Initialization

Initialization

During initialization, the IMS log-based ECCR performs the following tasks:
  • Checks and loads the capture registrations.
  • Determines which of the RECON data sets that are specified in the ECCR input parameters is the current data set.
  • Uses the current RECON data set to determine which log data sets to process and the order in which to process them.
  • Opens a connection to the PowerExchange Logger and retrieves restart information.
  • Sets up searchable structures and allocates work buffers.