Table of Contents

Search

  1. Preface
  2. Part 1: PowerExchange Change Data Capture Introduction
  3. Part 2: CDC Components Configuration and Management
  4. Part 3: CDC Sources Configuration and Management
  5. Part 4: Change Data Extraction
  6. Part 5: Monitoring and Tuning
  7. Appendix A: CDC for z/OS Troubleshooting
  8. Appendix B: DTL__CAPXTIMESTAMP Time Stamps

ECCRNAME Parameter

ECCRNAME Parameter

Required. A name for the Datacom table-based ECCR.
ECCRNAME=
eccr_name
For the
eccr_name
variable, enter a 1- to 8-character alphanumeric string.
No default. However, the z/OS Installation Assistant generates an ECCR name that begins with the
PowerExchange Agent / Logger Prefix
value followed by DCMEC, for example, PWXDCMEC.
  • The ECCR uses this parameter value for the following purposes:
    • To connect to the PowerExchange Logger to write change data
    • As the member name that joins the XCF group of the PowerExchange Logger
    • As part of the ECCR-UOW field in the control information for each change record that is written to PowerExchange Logger log files
  • If you change the ECCRNAME value, the ECCR cannot warm start from where it last left off.
  • The ECCR name must be unique within a PowerExchange Logger group.
  • Informatica recommends that you use the same value for the ECCRNAME parameter and the Datacom ECCR started task or job name. This practice lets you to easily identify the Datacom ECCR when reviewing messages and data from the PowerExchange Logger.