Table of Contents

Search

  1. Preface
  2. Part 1: PowerExchange Change Data Capture Introduction
  3. Part 2: CDC Components Configuration and Management
  4. Part 3: CDC Sources Configuration and Management
  5. Part 4: Change Data Extraction
  6. Part 5: Monitoring and Tuning
  7. Appendix A: CDC for z/OS Troubleshooting
  8. Appendix B: DTL__CAPXTIMESTAMP Time Stamps

ECCRNAME Parameter

ECCRNAME Parameter

A name for the IDMS log-based ECCR.
ECCRNAME=
eccrname
For the
eccrname
variable, enter an alphanumeric string from 1 to 8 characters long.
No default. However, the z/OS Installation Assistant generates an ECCR name that begins with the
PowerExchange Agent / Logger Prefix
value followed by IDLEC, for example, PWXIDLEC.
  • The IDMS log-based ECCR uses the ECCRNAME value for the following purposes:
    • The ECCR name for connecting to the PowerExchange Logger to write change data
    • The member name that joins the XCF group of the PowerExchange Logger
    • As part of the ECCR-UOW field in the control information for each change record written to PowerExchange Logger log files
  • This name must be unique within a PowerExchange Logger group.
  • If you change the ECCRNAME value, the ECCR cannot warm start from its last position in the change stream. You must cold start the ECCR. Also,
    in-flight
    UOWs might occur in the PowerExchange Logger log files. To clean up in-flight UOWs, use the PowerExchange Logger RESOLVE_INDOUBT command.
  • Informatica recommends that you use the same value for both the ECCRNAME parameter and the IDMS log-based ECCR started task name or job name. This practice allows you to easily identify the IDMS log-based ECCR when reviewing messages and data from the PowerExchange Logger.

0 COMMENTS

We’d like to hear from you!