Table of Contents

Search

  1. Preface
  2. PowerExchange Installation and Upgrade Overview
  3. Installation Planning
  4. Upgrade Planning
  5. Installing and Upgrading PowerExchange on IBM i
  6. Installing and Upgrading PowerExchange on Linux and UNIX
  7. Installing and Upgrading PowerExchange on Windows
  8. Installing and Upgrading PowerExchange on z/OS
  9. Appendix A: Upgrade Considerations
  10. Appendix B: PowerExchange Environment
  11. Appendix C: Manual Installation on IBM i

Installation and Upgrade Guide

Installation and Upgrade Guide

Updated Components in the PowerExchange ECCR CRG.LOAD Library for IMS Synchronous CDC

Updated Components in the PowerExchange ECCR CRG.LOAD Library for IMS Synchronous CDC

PowerExchange 10.5.5 contains components of the BMC Software BMC AMI Online Reorg for IMS and BMC AMI Database Integrity for IMS products. PowerExchange provides the latest available version of these components.
These components are also part of other BMC Software products such as BMC AMI Fast Path Online Restructure for IMS (formerly Fast Path Online Restructure/EP), BMC AMI Online Reorg for IMS (formerly BMC MAXM Reorg/Online for IMS), and CONCURRENT REORG.
You can use either the CRG software that PowerExchange delivers or one of these BMC Software products, which include the CRG code.
If you have a supported version of one of the BMC Software products, you must use the BMC Software product instead of the CRG software provided in the CRG.LOAD library.
If you use one of the BMC Software products, ensure that the product meets the minimum version that PowerExchange requires for IMS synchronous CDC, as described in the "IMS Synchronous Change Data Capture" chapter of the
PowerExchange CDC Guide for z/OS
.
Also, note that PowerExchange Version 10.5.5 has been certified with the following BMC product versions, which provide the CRG code:
  • BMC AMI Online Reorg for IMS: Version 5.1.00 Level 2307 plus BMC fixes BQQ6601 and BQQ6695
  • BMC AMI Database Integrity for IMS: Version 5.1.00 Level 2307 plus BMC fixes BQQ6601 and BQQ6695
  • BMC AMI Fast Path Online Restructure for IMS: Version 4.1.00 Level 2307 plus BMC fix BQQ6106
If you use a product version earlier than the certified version, consider upgrading the product to the certified version.
If you use the CRG software, after you upgrade PowerExchange, run the CRGUMOD or CRGCLINK job in the
hlq
.SAMPLIB library again to install DBRC modifications. Otherwise, events such as abends might cause CDC to fail in the DLIODDCx module when the IMS synchronous ECCR tries to capture changes for a source segment. After you run the CRGUMOD or CRGCLINK job, restart the IMS control region.

0 COMMENTS

We’d like to hear from you!