Enter or review information about the Datacom tables to use for bulk data movement and CDC operations.
Datacom
Enables CA Datacom tables as a data source for bulk data movement.
This setting corresponds to the <dcomexec> variable in the INSTPARM file.
Table Based CDC
Enables CA Datacom tables as data sources for Database table-based CDC.
This setting corresponds to the <dcomtblbasedcdc> variable in the INSTPARM file.
Load Library
The data set name of the Datacom load library.
Default is
DCOM.V10.TARGET.CAILIB
.
This setting corresponds to the <dcomload> variable in the INSTPARM file.
Customized Load
The data set name of the Datacom customized load library.
Default is
DCOM.V10.CUST1.CUSLIB
.
This setting corresponds to the <dcomcust> variable in the INSTPARM file.
Service Pack Library
The data set name of the Datacom service pack library, if one exists.
Default is
DCOM.V10.SP01LOAD
.
This setting corresponds to the <dcomspl> variable in the INSTPARM file.
IPC Library
The data set name of the Inter-Product Components (IPC) library. This library is a collection of common routines, similar to the CA90s or TNG framework, which enable the product to be insulated from the environment to facilitate speed of development.
Default is CAI.IPC.CAILIB.
This setting corresponds to the <dcomipc> variable in the INSTPARM file.
CA90 / TNG Library
The data set name of the CA90s or the TNG library.
Default is CAI.CAILIB.
This setting corresponds to the <dcomcai> variable in the INSTPARM file.
CXX Directory
The data set name of the Datacom CXX communication library.
Default is
DCOM.V10.CXX
.
This setting corresponds to the <dcomcxx> variable in the INSTPARM file.
Datacom Table Based Cleanup
Enables Datacom table-based CDC clean up.
By default, this option is cleared.
This setting corresponds to the <dcomcleanup> variable in the INSTPARM file.
Datacom Cleanup Interval
If you selected
Datacom Table Based Cleanup
, the number of seconds that the cleanup subtask must wait before removing changes from the Datacom CDC tables.
Default is 300.
This setting corresponds to the <dcomcleanupinterval> variable in the INSTPARM file.
Datacom CDC Base
The ID of the database that contains the change data.
Default is 2009.
This setting corresponds to the <dcomcdcbase> variable in the INSTPARM file.
Datacom MUF Name
The name of the Datacom MUF from which PowerExchange table-based CDC captures change data.
Default is MUFNAME.
This setting corresponds to the <dcomdbid2> variable in the INSTPARM file.
Advanced Parms
Enables you to define advanced parameters.
To change an advanced parameter value, complete the following steps:
In the
Value
column, click the cell for the parameter.
To sort parameters, click a column header. For example, to sort by parameter name, click the
Parameter Name
header.
Enter the parameter value, and click
OK
.
If you define advanced parameters, you cannot restore these parameters to default values by using the