Table of Contents

Search

  1. Preface
  2. PWX-10000 to PWX-10999
  3. PWX-11000 to PWX-15999
  4. PWX-16000 to PWX-23999
  5. PWX-25000 to PWX-35999
  6. PWX-36000 to PWX-36999
  7. PWX-37100 to PWX-37999
  8. PWX-38500 to PWX-38999
  9. DTL_BMG003 to DTL_RPS105I
  10. infacmd pwx Error Messages
  11. PWXPC Error Messages
  12. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 2

Message Reference Volume 2

PWX- 32031

PWX-
32031

CCSID
ccsid
is not in the DB2CODEPAGE parameter for subsystem
subsystem
.
The column has a CCSID value that is not specified in any CCSID parameter in the DB2CODEPAGE statement for the subsystem.
Processing stops.
In the DBMOVER configuration file, add the CCSID value for the column to one of the CCSID parameters in the DB2CODEPAGE statement for the subsystem.
If the EBCDIC_CCSID parameters contain valid CCSID values, add the CCSID value for the column to one of the ASCII_CCSID or UNICODE_CCSID parameters in the DB2CODEPAGE statement. Respect the single, double, or mixed length attributes.

0 COMMENTS

We’d like to hear from you!