PWX-33265

PWX-
33265

Active registration <
registration_name
> does not match selection criteria for any defined group
The specified capture registration did not match any of the selection masks in the GROUPDEFS configuration file. The GROUPDEFS file defines groups of registrations for which the PowerExchange Logger for Linux, UNIX, and Windows captures change data to separate sets of log files.
Processing continues. The PowerExchange Logger does not capture change data for the source object that is associated with the registration.
Edit the selection masks in the GROUPDEFS configuration file to select the registration for PowerExchange Logger processing, if necessary.