PWX- 36108

PWX-
36108

ORAD: Log gap detected processing THREAD#
thread_number
. Last log sequence found was
sequence_number
, next sequence found is
sequence_number
, SCN
scn
.
The PowerExchange Express CDC for Oracle log reader detected a gap in the sequence of redo log files for the specified Oracle thread. The sequence numbers of the log files must be in consecutive, ascending order.
PowerExchange Express CDC processing ends abnormally.
Restore the redo log files that are needed to correct the log gap. If you cannot restore these log files, rematerialize the target. Then cold start the CDC session.