Table of Contents

Search

  1. Preface
  2. PWX-10000 to PWX-10999
  3. PWX-11000 to PWX-15999
  4. PWX-16000 to PWX-23999
  5. PWX-25000 to PWX-35999
  6. PWX-36000 to PWX-36999
  7. PWX-37100 to PWX-37999
  8. PWX-38500 to PWX-38999
  9. DTL_BMG003 to DTL_RPS105I
  10. infacmd pwx Error Messages
  11. PWXPC Error Messages
  12. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 2

Message Reference Volume 2

PWXPC_ 12122

PWXPC_
12122

Commit on EOF attribute for session must be disabled to guarantee restart.
To guarantee that proper restart processing occurs, the PWXPC CDC reader must control commit processing to the targets. However, the
Commit On End Of File
option is enabled. When this option is enabled and a CDC sessions ends, PowerCenter performs a final commit after the PWXPC CDC reader has ended. This final commit can failure or duplicate data when the CDC session is restarted because the restart tokens do not match the state of the targets.
Processing continues.
Disable the
Commit On End Of File
attribute on the Properties tab of the CDC session.