Informatica Data Quality
- Informatica Data Quality 10.4.0
- All Products
Property
| Description
|
---|---|
Start Value
| Start value of the generated sequence that you want the Integration Service to use if you use the Cycle option. If you select Cycle, the Integration Service cycles back to this value when it reaches the end value.
Default is 0.
Maximum value is 9,223,372,036,854,775,806.
|
End Value
| Maximum value that the Integration Service generates. If the Integration Service reaches this value during the session and the sequence is not configured to cycle, the session fails.
Maximum value is 9,223,372,036,854,775,807.
|
Increment Value
| Difference between two consecutive values from the NEXTVAL port.
Default is 1.
Must be a positive integer.
Maximum value is 2,147,483,647.
|
Cycle
| If enabled, the Integration Service cycles through the sequence range and starts over with the start value.
If disabled, the Integration Service stops the sequence at the configured end value. The Integration Service fails the session with overflow errors if it reaches the end value and still has rows to process.
|