Table of Contents

Search

  1. Preface
  2. Introduction to Informatica Edge Data Streaming
  3. Licenses
  4. Using Informatica Administrator
  5. Creating and Managing the Edge Data Streaming Service
  6. Edge Data Streaming Entity Types
  7. Edge Data Streaming Nodes
  8. Data Connections
  9. Working With Data Flows
  10. Managing the Edge Data Streaming Components
  11. Security
  12. High Availability
  13. Disaster Recovery
  14. Monitoring Edge Data Streaming Entities
  15. Appendix A: Troubleshooting
  16. Appendix B: Frequently Asked Questions
  17. Appendix C: Regular Expressions
  18. Appendix D: Command Line Program
  19. Appendix E: Configuring Edge Data Streaming to Work With a ZooKeeper Observer
  20. Appendix F: Glossary

User Guide

User Guide

Troubleshooting Monitoring Tab Views

Troubleshooting Monitoring Tab Views

A
EDS Node
appears inactive on the Monitoring tab of the Administrator tool.
A
EDS Node
appears inactive in the following situations:
  • The
    EDS Node
    might not be running. Verify the status of the
    EDS Node
    . If the
    EDS Node
    is not running, start it.
    If the
    EDS Node
    is running, navigate to the following directory:
    <EDS Node Installation Directory>/node/logs/
    View the
    <node name>-node.log
    file for exceptions and correct them.
  • The
    Administrator Daemon
    might not be running. Verify the status of the
    Administrator Daemon
    . If the
    Administrator Daemon
    is not running, start it.
    If the
    Administrator Daemon
    is running, navigate to the following directory:
    <Administrator Daemon Installation Directory>/admind/logs/
    Check the
    admind.log
    file for exceptions and correct them.
  • The
    EDS Node
    is configured incorrectly.
    Navigate to the following directory:
    <EDS Node Installation Directory>/node/config/
    Verify that the
    zkservers
    field in the
    node.cnf
    file is pointing to the correct Apache ZooKeeper server URL.
A source service or a target service appears inactive on the Monitoring tab.
This can occur if the source service or a target service is configured incorrectly.
Navigate to the following directory:
<EDS Node Installation Directory>/node/logs/
View the
<node name>-node.log
file exceptions in source or target, and correct them.
The monitoring data indicates that the source statistics are increasing continuously, but the target statistics received are not increasing.
This error occurs in the following situations:
  • The
    Topic resolution type
    field is set to
    Unicast
    in the data flow properties, and LBMRD is not running on the address specified in the
    Resolver daemon
    field. In the
    Data Flows
    pane, click the data flow whose properties you want to view. The
    Entity Details
    pane appears. Click
    Connections
    tab and click the connection. Verify that LBMRD is running on the address specified in the
    Resolver daemon
    field.
  • The
    Topic resolution
    field is set to
    Multicast
    in the data flow properties, and the source service and target service are on different machines. Verify that the machines running the source service and target service have multicast enabled. Also verify that the machines are configured in the same multicast group.
  • The transformation might not be applied correctly. Verify that you have configured the transformation correctly.
To determine whether multicast is enabled in your environment, perform the multicast capability test.
For more information about the multicast capability test, see the article
Informatica MTools
on MySupport at https://community.informatica.com/solutions/1470.
I use a Static File source service in my data flow and have specified the processed file directory. The files have been moved to the processed file directory, but the data is not received by the target service.
This situation occurs when the data is not sent to the target service because the files have been ignored. The Static File source service moves the files sent to the target service and the ignored files to the processed file directory. The Static File source service ignores the files in the following situations:
  • The delimiter is EOF and the value of the
    Maximum Event Size
    property is less than the size of the file the source service is reading from.
  • The files are older than the files already processed by the Static File source service.
The transformation statistics in the Grid view of the Administrator tool show a higher value in the events received column compared to the value in the events sent column.
This discrepancy might occur when the source service splits the events into multiple events based on the delimiter settings that you have specified for the source service. When the transformation receives the events from the source service, it also includes the split events in the events received statistic. As a result, the events received column of the transformation table displays a higher value than the value that appears in the events sent column of the source entity table.
You can ignore the difference in values as it has no impact on the functionality of the source service.
The monitoring data indicates that the Bytes Received, Events Received, Bytes Sent, and Events Sent statistics are displaying less than expected values.
This behavior occurs if you restart the EDS Node that the source service or target service is associated with. There is no workaround for this behaviour.